II - 5 Remote Switch Data Output
Example 6: Probing function Circle Center
First center point coordinate, e.g. CCX = –1616.3429 mm. Second
center point coordinate, e.g. CCY = +4362.9876 mm, (Circle Center
X axis, Circle Center Y axis; coordinates depend on working plane).
Circle diameter DIA = 1250.0500 mm
1 Colon
2 +/– sign, or Blank Space
3 2 to 7 places before the decimal point
4 Decimal point
5 1 to 6 places after the decimal point
6 Unit: blank space for mm, “ for inches
7R for Radius, D for Diameter display
8 Carriage return
9 Blank line (Line Feed)
CCX
:-1 6 1 6 . 3 4 2 9 R <CR> <LF>
CCY
:+4 3 6 2 . 9 8 7 6 R <CR> <LF>
DIA
: 1 2 5 0 . 0 5 0 0 R <CR> <LF>
12345678 9