100S General Purpose Reference Manual 25
Reference
Electrical Specifications
Follow these specifications when installing your 100S GP system.
Characteristic
Operating conditions
0° to 40°C (32° to 104°F)
25% to 85% relative humidity
(non-condensing)
Storage conditions
-40° to 60°C (-40° to 140°F)
25% to 85% relative humidity
(non-condensing)
100 - 240 V~
50 - 60Hz
25 VA max
Input requirements:
Voltage
Frequency
Current
Fuse
500 mA, slo-blo
Position signals: channels A & B
TTL square wave signal in quadrature
(90° nominal phase relationship)
Maximum input rate: 70 kHz
Scale input
This device complies with Part 15 of the
FCC Rules. Operation is subject to the fol-
lowing two conditions: (1) this device may
not cause harmful interference, and (2) this
device must accept any interference received,
including interference that may cause
undesired operation.
Size 9.875” x 4.679” x 4.75”
Weight
4 lbs., 2 oz.
Mounting
Bottom; two 1/4”-20 threaded inserts
FCC compliance
CE compliance
ETL compliance
ETLc compliance
For Europe
For United States