100S General Purpose Reference Manual 9
Setup
Scale Resolution
To ensure accurate readings, the scale resolution shown for each axis
must correspond with the resolution of the scales on your machine.
To change the scale resolution:
If necessary, choose “Scale Resolution” from the Setup menu.
(Press SETUP and then the ENTER key until the screen appears).
Press the appropriate axis key (X, Y or Z) until the appropriate resolu-
tion appears. Choose 0.01 mm for 10µm (0.0005”) scales, 0.005 mm
for 5µm (0.0002”) and 0.001 mm for 1µm (0.00005”)scales.
Repeat the procedure for each axis.
Press ENTER to continue with Setup.
Count Direction
Use the count direction setting to define the positive counting direction
for each scale. The direction will be displayed as a “1” or a “2” (the num-
bers are not assigned to a particular direction). You only need to change
the count direction if the scale is counting in the negative
direction during a positive move, or vice versa.
Refer to Conventions on pg. 29 for more guidelines.
To change the count direction:
Move to the “Count Direction” display in the Setup mode. (Press
SETUP and then the ENTER key until “Ct dir” appears).
Press the appropriate axis key (X, Y or Z). The current count direction
(1 or 2) will appear.
After you complete setting your count direction, press ENTER to
continue with setup or press ENTER then SETUP to return to the
normal DRO display.